SCHEDULE GS-1 08
- GENERAL SERVICE (SMALL COMMERCIAL)
SUN RIVER ELECTRIC COOPERATIVE, INC.
EFFECTIVE  JANUARY 15, 2008

TYPE OF SERVICE:

            Three phase, 60 cycle at cooperative's available secondary voltage; or single phase, when three phase is not readily available and less than 50 KVA of installed transformer capacity is required, subject to the rules and regulations of the cooperative.

AVAILABILITY:

            To all members requiring three phase service; or single phase service of less than 50 KVA of installed transformer capacity.  Motors in excess of 10 HP must be three phase, unless approved by the cooperative.

MONTHLY RATE:

                        KVA Charge                            1st 20 KVA - No Charge
                       
All over 20 KVA                      $2.23/KVA

                        Base Rate                                 $24.00
           
Plus      1st 2500 kwhrs                         $.07119/kwhr
                       
All other kwhrs                         $.05209/kwhr

            The KVA charge will be established by a charge of $2.23 per KVA of total installed transformer capacity above 20 KVA, and below 50 KVA.

MINIMUM MONTHLY CHARGE:

            The minimum monthly charge shall be the higher of the following:

                  1.    The cost for service as calculated by the rates specified.
   
               2.    $1.00 per KVA installed transformer capacity over 20 KVA, plus the base charge.

MINIMUM ANNUAL CHARGE FOR SEASONAL SERVICE:

            At the option of the cooperative, consumers requiring service only during certain seasons not exceeding six (6) months per year may make an advance payment annually of either twelve times the minimum monthly charge or the standard annual minimum set forth in the Seasonal Service Policy, whichever is larger. 

POWER FACTOR ADJUSTMENT:

            The consumer agrees to maintain unity power factor as nearly as practicable.  At the option of the cooperative the power factor and KW demand of the consumer shall be measured and the monthly bills adjusted.  Such adjustment shall be made by increasing the bills by 1% of each 1% by which the average power factor is less than 95% lagging.  At the request of the cooperative the consumer agrees to apply corrective measures to his load to bring the average power factor to 95% lagging, or higher.

 

 

Home ] Home ] History ] Ripples Newsletter ] Community Service ] Military_Appreciation ] Programs ] Emergency Numbers ] Call Before You Dig ] Cooperative Principles ] Trustees ] Employees ] Jobs ] Safety ] Apply for Service ] Billing Rates ] Capital Credits ] Scholarships ] Customer Owned Generation ] Other Links ] Email ]